A new ICT system offers many advantages - but you will search in vain for a connection for existing door stations. With the TSA-a/b door intercom adapter, however, you can easily connect an older door intercom with up to 2 bell buttons to an analogue subscriber port of a modern ICT system.
Languages | Current version | ||
---|---|---|---|
Statements of conformity | V05 10/2022 | ||
Operation Guide | V02 09/2016 | ||
Instructions a/b Switching Module | V03 10/2020 | ||
Connection to Grothe | V01 | ||
Connection to Keil doorTEL DT 110 | V01 | ||
Connection to Ritto | V01 | ||
Connection to Siedle TLE 051, TLE 511, TM 511, TLM 511 (inkl. HT-611-01) | V01 | ||
Connection to Siedle TLE 051, TLE 511, TM 511, TLM 511 | V01 | ||
Connection to TFS-Dialog/TFS-Dialog Pro | V01 | ||
Connection to TFS-Dialog 101/102 | V01 | ||
Connection to Siedle TLM/TK 611 | V01 |
Standards:
- EN 55032:2015/A11:2020 replaces EN 55032:2015
- EN55035:2017/A11:2020 replaces EN 55024:2010
Note about qualified electrician complemented.
Note about door bell transformer complemented. Note about inflammable materials deleted.
Operating voltage: Values changed
Contact load capacity: Values changed
The COMpact 3000 analog/ISDN/VoIP PBXs don't feature an interface for FTZ-standard doorphones.
However, you can use analog doorphones such as our TFS-Dialog 20x/30x/universal plus. In addition, you can use the TSA - a / b use this converter can convert different doorphone to a / b port .
There is a humming in the door intercom, which is connected to the TSA-a/b. What could be the cause?
If the door intercom should work after installation, but still have an unpleasant humming noise, the following points can be considered:
Many Siedle call stations can be rewired internally so that the loudspeaker is led out at terminals 12 and 13 (without the built-in transistor amplifier). Connect terminal 12 of the Siedle module to one of the door intercom contacts (make contacts 1/2 on the TSA-a/b), connect the other door intercom contact to terminal LSP of the TSA-a/b. Connect terminal 13 of the Siedle module to the 0V contact on the TSA-a/b. This results in a greater maximum volume.